3 PM
32.0°C felt
same as doing nothing
Model of a simulated hot day, not a measurement. Drag the blinds, the fan and the sun.
Your flat · tap to change
The day, felt · drag to scrub
How the model works
- Simulated hot day, not live weather: outdoors swings from peak−8 °C at 3 am to the peak at 3 pm.
- One-room heat balance, 5-minute steps: glass gain (1.5 m² each, SHGC 0.75) + walls + ventilation + 60 W of people and fridge, into a heavy concrete flat (800 kJ/K).
- Shades: light blind passes 55 % of the sun, curtain 45 %, external shutter 15 %. My assumptions in typical ranges, not product data.
- Fan and breeze cool you, not the room: about 1.2 °C at 0.6 m/s, 1.8 at 0.9, 2.2 at 1.2, in the spirit of ASHRAE 55's elevated air speed method, interpolated by me. Fan reach fades over 3 m.
- Windows: “auto” opens only while outside is cooler than inside. One open: 3 air changes an hour; both: 10 and a 0.35 m/s breeze.
- Not for sizing a purchase. Humid heat and your own flat differ.